Old 06-19-2008, 10:50 AM   #1 (permalink)
Has many harvests
BudMaster
 
Hobo's Avatar
 

Location: Liberty City
Gallery: 26
Thanks: 42
Thanked 107 Times in 59 Posts
Hobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to behold
Activity Longevity
1/20 15/20
Today Posts
0/0 sssss1429
Default

I had a close friend of mine, who happens to be an electrician, wire me up a new circuit breaker in my panel, and ran a line and outlet up into my grow room. I just got a new airconditioner/dehumidifier and it drawsabout 7.5 amps, and i was running already 14 amps on a 15 amp breaker. So with this new circuit, i can run about 12 amps on one and 10 amps on another. This is a much safer way for me to operate.

Last edited by Hobo; 06-19-2008 at 05:17 PM.
Hobo is offline   Reply With Quote
Sponsored Advertisements

Old 06-19-2008, 12:13 PM   #2 (permalink)
GSR
Grower
BudMaster

 
GSR's Avatar
 

Location: After Harvest, Relaxation
Gallery: 2
Thanks: 201
Thanked 57 Times in 53 Posts
GSR is a glorious beacon of lightGSR is a glorious beacon of lightGSR is a glorious beacon of lightGSR is a glorious beacon of lightGSR is a glorious beacon of light
Activity Longevity
6/20 19/20
Today Posts
0/0 ssssss260
Default

You can rest at ease now for sure. I built my grow room with a seperate sub-panel, I can go away on vacation and not worry about a thing. Its realy worth it.
GSR is offline   Reply With Quote
Old 06-19-2008, 01:41 PM   #3 (permalink)
Tokin & smokin
Seedling

 
Framster's Avatar
 

Gallery: 0
Thanks: 0
Thanked 36 Times in 22 Posts
Framster has a spectacular aura aboutFramster has a spectacular aura about
Activity Longevity
0/20 18/20
Today Posts
0/0 sssssss78
Default

With the new line and breaker, your grow room is much safer. It is not a good idea to push your breakers to the limit. As a faulty breaker can cause a fire.
Framster is offline   Reply With Quote
Old 06-19-2008, 01:42 PM   #4 (permalink)
Teaching to grow
BudMaster

 
ClosetDWC's Avatar
 
Bump Ball Champion! Pushies Champion!
Tournaments Won: 1

Location: Bay area, C.A.
Gallery: 0
Thanks: 15
Thanked 56 Times in 44 Posts
ClosetDWC is a splendid one to beholdClosetDWC is a splendid one to beholdClosetDWC is a splendid one to beholdClosetDWC is a splendid one to beholdClosetDWC is a splendid one to beholdClosetDWC is a splendid one to beholdClosetDWC is a splendid one to behold
Activity Longevity
0/20 18/20
Today Posts
0/0 ssssss925
Default

agreed i had it the same way and it worked great for me a sub panel makes it a little easier to sleep at night.
__________________
Regard,
Closet-DWC

And remember just try and act NORML
ClosetDWC is offline   Reply With Quote
Old 06-19-2008, 02:11 PM   #5 (permalink)
Moderator
Moderator
 
jangel's Avatar
 

Location: Canada Home of the Polite, aiy!
Gallery: 9
Thanks: 2,289
Thanked 1,210 Times in 896 Posts
jangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond repute
Activity Longevity
20/20 11/20
Today Posts
0/0 sssss3847
Default

We put in 3 more breakers, but not a seperate panel. Total of 45 amps, but you only want to push each 15 amp breaker to 12 amps. I have one plug outlet per 15 amp breaker and wanted more but my man said it was plenty. I am sure he is right. I don't know the formula for figureing it out. Can anyone add that? I know there is one.
jangel is offline   Reply With Quote
Old 06-19-2008, 02:18 PM   #6 (permalink)
Has many harvests
BudMaster
 
ISO2BWELL's Avatar
 

Location: 'Tween a Rock and a Hard Spot..
Gallery: 132
Thanks: 334
Thanked 687 Times in 439 Posts
ISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud of
Activity Longevity
7/20 20/20
Today Posts
0/0 sssss2814
Default

Jangel,

You can run all the "plug in outlets" you want from one breaker...just don't exceed the capacity (cumulative) of the breaker.

I have a separate breaker box in my grow area, containing 2 @ 15A and 1 breaker at 30A (10/2 wire used for safety).

ISO
__________________
The Essence of Compassion

"Resolve to be tender with the young, Compassionate with the aged,
Sympathetic with the striving and tolerant of the weak and wrong......
...... because sometime in your life you have been guilty of all of these"


.



ATF x Purple Kush, Mango x Romulan, White Widow x Skunk#1, Purple Willie
ISO2BWELL is offline   Reply With Quote
Old 06-19-2008, 05:15 PM   #7 (permalink)
Moderator
Moderator
 
jangel's Avatar
 

Location: Canada Home of the Polite, aiy!
Gallery: 9
Thanks: 2,289
Thanked 1,210 Times in 896 Posts
jangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond reputejangel has a reputation beyond repute
Activity Longevity
20/20 11/20
Today Posts
0/0 sssss3847
Default

Oh I know that ISO, but say if you are running ONE 400w light fixture on one breaker, that is how many amps? Then add a fan or whatever and you are pretty much at max.

you do not want another plug pulling that kind of power off the same breaker. I have lots of power, and have it safely spred out, with all plugs GFI's.
jangel is offline   Reply With Quote
Old 06-19-2008, 05:15 PM   #8 (permalink)
Has many harvests
BudMaster
 
Hobo's Avatar
 

Location: Liberty City
Gallery: 26
Thanks: 42
Thanked 107 Times in 59 Posts
Hobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to behold
Activity Longevity
1/20 15/20
Today Posts
0/0 sssss1429
Default

besides the breaker itself, there are circuit cut offs on all my surge protectors :D
__________________

MEDICATE \m/ >¿< \m/

www.greenlightnin.com - The best in Hydroponic Nutrients.

My Current Grow Journal...
http://www.greenpassion.org/f24/hobo...-welcome-2641/



PS i am a pathological liar, and have illusions of grandeur. I post pictures of pot plants i found on the internet and i have never nor will i ever consider the cultivation of marijuana, as it is illegal.
Hobo is offline   Reply With Quote
Old 06-19-2008, 05:20 PM   #9 (permalink)
Has many harvests
BudMaster
 
ISO2BWELL's Avatar
 

Location: 'Tween a Rock and a Hard Spot..
Gallery: 132
Thanks: 334
Thanked 687 Times in 439 Posts
ISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud ofISO2BWELL has much to be proud of
Activity Longevity
7/20 20/20
Today Posts
0/0 sssss2814
Default

Quote:
Originally Posted by jangel View Post
Oh I know that ISO, but say if you are running ONE 400w light fixture on one breaker, that is how many amps? Then add a fan or whatever and you are pretty much at max.

you do not want another plug pulling that kind of power off the same breaker. I have lots of power, and have it safely spred out, with all plugs GFI's.
On a 15 amp circuit you could safely run 2 of the 400W HID lights, plus a intake or exhaust fan. 400W = about 4 amps (in general, with room to spare), so, 2 of them would be 8 amps, plus a 2-3 amp fan = 10 amps. VERY safe for a 15 amp circuit if that is all that is on it.

ISO
__________________
The Essence of Compassion

"Resolve to be tender with the young, Compassionate with the aged,
Sympathetic with the striving and tolerant of the weak and wrong......
...... because sometime in your life you have been guilty of all of these"


.



ATF x Purple Kush, Mango x Romulan, White Widow x Skunk#1, Purple Willie
ISO2BWELL is offline   Reply With Quote
The Following User Says Thank You to ISO2BWELL For This Useful Post:
jangel (06-19-2008)
Old 06-19-2008, 11:40 PM   #10 (permalink)
Has many harvests
BudMaster
 
Hobo's Avatar
 

Location: Liberty City
Gallery: 26
Thanks: 42
Thanked 107 Times in 59 Posts
Hobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to beholdHobo is a splendid one to behold
Activity Longevity
1/20 15/20
Today Posts
0/0 sssss1429
Default

amps= watts/volts

1000 watts is about 9 amps at 110 volts.

a constant load is considered 4 hours straight more, a 15 amp breaker can safely run 14 amps or so constantly and up to 15 technically on a non constant load.

so a 15 amp breaker should be able to take about 1400 watts constantly and close to 1600 on non constant.
__________________

MEDICATE \m/ >¿< \m/

www.greenlightnin.com - The best in Hydroponic Nutrients.

My Current Grow Journal...
http://www.greenpassion.org/f24/hobo...-welcome-2641/



PS i am a pathological liar, and have illusions of grandeur. I post pictures of pot plants i found on the internet and i have never nor will i ever consider the cultivation of marijuana, as it is illegal.
Hobo is offline   Reply With Quote
The Following User Says Thank You to Hobo For This Useful Post:
jangel (06-20-2008)
Reply

Bookmarks

Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On

Similar Threads
Thread Thread Starter Forum Replies Last Post
Breaker switched during flowering.... IceIceBaBy Indoor Growing 7 06-03-2008 11:07 PM
how much extra potency does curing provied??? lightmyfire Harvest, Hash, kief & Curing 28 12-10-2007 07:19 PM
new mod installed greenpassion Suggestions & Support 13 11-29-2007 12:51 AM


All times are GMT -4. The time now is 03:31 PM.


Powered by vBulletin® Version 3.7.0
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Friendly URLs by vBSEO 3.2.0 RC5 ©2008, Crawlability, Inc.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39